Check, Compile, and Run from the Command Line¶
The IronPLC editor extension can check, compile, and run programs directly in the editor. If you prefer the command line — for example, to integrate with a CI/CD pipeline or a build script — this guide shows how to use the ironplcc and ironplcvm tools directly.
Note
This guide assumes you have installed the IronPLC Compiler. See Installation if you have not already installed it.
Open a Terminal¶
Open a terminal inside your development environment:
In Visual Studio Code or Cursor, select from the main menu.
The terminal should open in your project directory.
Check a Program¶
Run the following command to check your program for errors:
ironplcc check main.st
On success, the command produces no output. If there are errors, IronPLC prints diagnostics with the file name, line number, and a description of the problem.
Compile a Program¶
Compile your program into a bytecode container:
ironplcc compile main.st --output main.iplc
On success, the command creates the main.iplc file. This file
contains the compiled bytecode that the IronPLC virtual machine can execute.
Run a Compiled Program¶
Run the compiled program in the IronPLC virtual machine:
ironplcvm run main.iplc --scans 1 --dump-vars
The --scans 1 flag runs one scan cycle, and --dump-vars prints the
value of every variable after execution. You should see output like:
Button: FALSE
Buzzer: TRUE
Compile and Run with Multiple Files¶
When compiling multiple files, pass all of them to the compiler:
ironplcc compile main.st config.st --output main.iplc
The compiled output is the same — IronPLC merges all source files before compiling.
Run Multiple Scan Cycles¶
To observe how state changes over time, increase the number of scan cycles. For example, with a program that uses a timer:
ironplcc compile main.st --output main.iplc
ironplcvm run main.iplc --scans 10 --dump-vars
You should see output showing the timer’s state:
Button: FALSE
Buzzer: TRUE
PulseTimer.IN: TRUE
PulseTimer.PT: T#500ms
PulseTimer.Q: TRUE
PulseTimer.ET: T#1000ms
The timer’s elapsed time (ET) shows how long it has been running.
After enough scan cycles, Q becomes TRUE and the buzzer turns on.
See Also¶
ironplcc — full ironplcc command reference
ironplcvm — full ironplcvm command reference
Quick start tutorial — quickstart tutorial (uses the editor instead of the command line)