P4065¶
- Code
P4065
- Message
CONTINUE statement is not inside a loop
This error occurs when a CONTINUE statement appears outside of a loop. CONTINUE is only valid inside FOR, WHILE, or REPEAT loops, where it goes on with the next iteration of the innermost enclosing loop.
Example¶
The following code will generate error P4065:
PROGRAM main
VAR
x : INT;
END_VAR
x := 1;
CONTINUE; (* Error: not inside a loop *)
END_PROGRAM
The CONTINUE statement is in the program body but not inside any loop.
To fix this error, move the CONTINUE statement inside a loop or remove it:
PROGRAM main
VAR
x : INT;
odd : INT;
END_VAR
FOR x := 1 TO 10 BY 1 DO
IF x MOD 2 = 0 THEN
CONTINUE; (* Valid: inside a FOR loop *)
END_IF;
odd := odd + 1;
END_FOR;
END_PROGRAM
See CONTINUE.
Think IronPLC is wrong about this?
If you believe this diagnostic is incorrect, open an issue on GitHub with a small sample that demonstrates the problem.