P4103¶
- Code
P4103
- Message
Trailing comma in a call’s argument list requires choosing a dialect or –allow-trailing-call-comma flag
This error occurs when a call’s argument list has a comma before the closing
parenthesis without the --allow-trailing-call-comma compiler flag.
The IEC 61131-3 standard grammar (Annex B) separates arguments with commas and has none after the last one. A trailing comma is an extension.
Example¶
The following code will generate error P4103:
PROGRAM main
VAR
drive : FB_Drive;
END_VAR
drive(Enable := TRUE, );
END_PROGRAM
To fix this error, either remove the comma:
PROGRAM main
VAR
drive : FB_Drive;
END_VAR
drive(Enable := TRUE);
END_PROGRAM
Or enable the extension:
Pass the --allow-trailing-call-comma flag to enable it, or select a dialect that includes it. See
Enabling Dialects and Features for the dialects and flags
reference.
Think IronPLC is wrong about this?
If you believe this diagnostic is incorrect, open an issue on GitHub with a small sample that demonstrates the problem.